Sloan Crown Parts Breakdown

1
# 80839
C.P. COVER
2
-
COVER O-RING
3
# 80840
CP HANDLE AND COVER TRIM RING KIT (Includes items 3A and 3B)(Crown II Only)
# 80841
PVDPB HANDLE AND COVER TRIM RING KIT (Includes items 3A & 3B) (Crown II Only)
# 80842
PVDGP HANDLE AND COVER TRIM RING KIT (Includes items 3A & 3B) (Crown II Only)
# 80843
PVDBN HANDLE AND COVER TRIM RING KIT (Includes items 3A & 3B) (Crown II Only)
# 8084
SF HANDLE AND COVER TRIM RING KIT (Includes items 3A & 3B) (Crown II Only)
3A
-
PVDPB COVER TRIM RING (Crown II Only)
-
PVDGP COVER TRIM RING (Crown II Only)
-
PVDBN COVER TRIM RING (Crown II Only)
-
SF COVER TRIM RING (Crown II Only)
3B
-
PVDPB HANDLE TRIM RING (Crown II Only)
-
PVDGB HANDLE TRIM RING (Crown II Only)
-
PVDBN HANDLE TRIM RING (Crown II Only)
-
SF HANDLE TRIM RING (Crown II Only)
4
# 80845
PISTON KIT - 1.6 GPF CLOSET
# 80846
PISTON KIT - 1.0 GPF URINAL
# 80847
PISTON KIT - 0.5 GPF URINAL
Scroll down for Piston Kit Components
5A
# 80848
ADA COMPLIANT HANDLE ASSEMBLY CP
B-30-A
5B
# 08069
ADA COMPLIANT HANDLE ASSEMBLY CP
B-73-A
6A
# 80849
HANDLE REPAIR KIT
CR-1007
6B
# 08439
HANDLE REPAIR KIT
B-51-A
7
# 08065
HANDLE GASKET
8
# 08902
HANDLE GRIP SUB-ASSEMBLY ADA
9A
-
SLEEVE
9B
# 08067
CP SOCKET ASSEMBLY
10A
-
HANDLE SOCKET
10B
# 08054
CP HANDLE COUPLING
11
# 08465
3/4 x 9" VACUUM BREAKER
# 08466
1-1/4 x 9" VACUUM BREAKER
# 08467
1-1/2 x 9" VACUUM BREAKER
12
# 08438
HIGH BACK PRESSURE VACUUM BREAKER REPAIR KIT
13
# 80831
3/4" X 9" SPUD COUPLING ASSEMBLY
# 80832
1-1/4" X 9" SPUD COUPLING ASSEMBLY
# 80833
1-1/2" X 9" SPUD COUPLING ASSEMBLY
14
# 08040
STOP COUPLING
15
# 08039
ADJ. TAILPIECE 2-1/16"
16A
# 08037
"O" RING
16B
# 08038
LOCKING RING
17
# 80791
1" SCREWDRIVER BAK CHECK STOP CP
# 80837
3/4" SCREWDRIVER BAK CHECK STOP CP
18
# 08032
CONTROL STOP REPAIR KIT * 
# 08033
CONTROL STOP REPAIR KIT  ** 
19
# 08536
CP BONNET  * 
-
CP BONNET ** 
20
# 08035
LOCKING VANDAL RESISTANT CONTROL *  
STOP CAP INCLUDES H-573 STOP CAP CP   AND H-648 FRICTION RING   
# 8036
LOCKING VANDAL RESISTANT CONTROL**
STOP CAP    
21
# 80850
VANDAL RESISTANT  *
CONTROL STOP CAP ASSEMBLY  
22
# 08419
CONTROL STOP CAP WITH BUMPER*
(-YO VARIATION)  
23
# 81670
CONTROL STOP CAP W/EXTENDED *  BUMPER (-YG VARIATION)   
# 54708
HANDLE ADAPTER FOR OPTIMA VERSION (not shown)
*  For use with H-700-A 1" & 3/4" and H-600-A
1" Screwdriver Bak Chek Control Stops
* *  For use with H-600-A 3/4" Screwdriver Bak Chek Control Stops

To place an order,
call us toll free at
1-800-442-6622



ITEM 4 : PISTON KIT COMPONENTS

     
 
 
     
 
A N/A INSIDE COVER SUB-ASSEMBLY
B * * * PISTON COVER
C # 81671 MOLDED CUP
D # 08032SPRG SPRING
E * * * RELIEF VALVE
F # 81672 RELIEF VALVE SEAT
G * * * PISTON BODY
H # 80838 MAIN SEAT
I # 81674 FILTER O-RING
J # 05160 O-RING
* * * Not Available Separately
 

TROUBLESHOOTING GUIDE FOR
SLOAN CROWN & CROWN II FLUSHOMETERS
     
IMPORTANT: The Crown II/Crown Flushometer is engineered for quiet operation. Excessive water flow creates noise, while too little water flow may not satisfy the needs of the fixture. Proper adjustment is made when plumbing fixture is cleansed after each flush without splashing water out from the lip AND a quiet flushing cycle is achieved.
 
ATTENTION INSTALLERS: With the exception of the control stop inlet, DO NOT USE pipe sealant or plumbing grease on any valve component or coupling! To protect the chrome or special finish of Sloan Flushometers, DO NOT USE toothed tools to install or service these valves. Use our #8047 Super Wrench or other smooth-jawed wrench to secure couplings. Regulations for low consumption fixtures (1.6 gpf closets and 1.0 gpf urinals) prohibit use of higher flush volumes.

1
PROBLEM:
  VALVE DOES NOT FUNCTION
  CAUSE:  
  A) Control Stop or Main Valve is closed.
  B) Handle Assembly is worn.
  C) Relief Valve is worn and sticking in UP position.
  SOLUTION:  
  A) Open control stop or main valve.
  B) Install Sloan Handle Repair Kit (CR-1007 for Crown II, B-51-a for Crown,) or replace handle.
  C) Replace piston.

2 PROBLEM:
  INSUFFICIENT VOLUME OF WATER TO ADEQUATELY SIPHON FIXTURE.
  CAUSE:  
  A) Control Stop not open enough.
  B) Urinal piston parts inside a closet valve.
  C) Low consumption valve installed on a non-low consumption fixture.
  D) Inadequate volume or pressure at supply.
  SOLUTION:  
  A) Adjust control stop for desired delivery of water.
  B) Replace piston parts with proper closet piston
  C) Replace with proper flushometer
  D) Increase water pressure or supply (flow) to valve. Call Equiparts for assistance at 800-442-6622.

3
PROBLEM:
  LENGTH OF FLUSH TOO SHORT, OR VALVE CLOSES OFF IMMEDIATELY
  CAUSE:  
  A) Piston assembly is not hand-tight.
  B) Enlarged bypass orifice from corrosion or damage.
  C) Urinal piston in closet Flushometer
  D) Low consumption piston installed in non-low consumption fixture.
  E) Handle assembly worn.
  SOLUTION:  
  A) Screw the assembly hand-tight.
  B) Install new inside parts kit to correct problem and update flushometer.
  C) Replace piston with proper closet piston.
  D) Replace with proper flushometer. Crown Flushometers are not available with flush volume higher than 1.6 gpf.
  E) Install Sloan Handle Repair Kit (CR-1007 for Crown II, B-51-a for Crown.)
   
 
4
PROBLEM:
  LENGTH OF FLUSH TOO LONG OR FAILS TO CLOSE OFF
  CAUSE:  
  A) Piston is not seating properly, bypass orifice is clogged because of foreign material, or bypass orifice is clogged by an invisible gelatinous film from "over-treated" water.
  B) Line pressure has dropped and is not sufficient to force Relief Valve to seat.
  C) CR-125-A main seat is fouled with debris, or is worn.
  SOLUTION:  
  A) Disassemble the working parts and wash thoroughly. Note: size of the orifice in the by-pass is of utmost importance in the proper metering of water into the upper chamber of the valve. DO NOT enlarge or damage this orifice. Replace piston if cleaning does not correct problem.
  B) Shut off all control stops until pressure has been restored, then open them again.
  C) Clean or replace CR-125-A main seat.

5 PROBLEM:
LEAKING AT HANDLE ASSEMBLY
CAUSE:
A) The B-85 seal may have deteriorated.
B) Handle gasket has been omitted.
C) Valve handle bushing is worn
D) Handle trim ring is reversed, preventing gasket from sealing. (Crown II only)
SOLUTION:
A) Install new B-85 seal. NOTE: The B-85 seal will easily slide onto the bushing if it is wet.
B) Install A-31 handle gasket or Sloan Handle Repair Kit
C) Install Sloan Handle Repair Kit (CR-1007 for Crown II, B-51-a for Crown,) or replace handle.
D) Flip handle trim ring (CR-113) and reinstall handle assembly. (Crown II only)
 
 
 

PISTON
IDENTIFICATION
CHART

Closet
Urinal
Urinal
# 00000
# 00000
# 00000
1.6 gpf
1.0 gpf
0.5 gpf
CAP COLOR
Green
Yellow
Red
PISTON COLOR
Clear
Clear
Clear
BARREL
Large Ribs
Small Ribs
Small Ribs
GROOVES
1
1
2
   
Equiparts  •   1003 Main St.  •  Pittsburgh, PA 15215
Pittsburgh: 412-781-9100   •  Toll Free: 800-442-6622   •   Fax: 412-781-3085
© 2010 Equiparts Corp. All Rights Reserved.