| 5 |
PROBLEM: |
|
|
FLUSHOMETER VALVE CLOSES
IMMEDIATELY
(SHORT FLUSH)
|
|
|
|
CAUSE: |
|
|
A) WORN OR DAMAGED
DIAPHRAGM ASSEMBLY |
|
|
B) Handle assembly
is damaged. |
|
|
C) Low
consumption diaphragm assembly is installed on water saver/
conventional fixture or urinal diaphragm assembly is installed
on closet fixture. |
|
|
|
SOLUTION: |
|
|
A) Replace
diaphragm assembly. |
|
|
B) Replace
B-73-A handle or repair with B-51-A
handle repair kit. |
|
|
C) Determine
the required flush volume (see label on valve or markings on
fixture). Replace diaphragm assembly or relief valve for appropriate
flush volume of fixture. |
|
| |
|
| |
| 6 |
PROBLEM: |
|
|
LENGTH OF FLUSH IS TOO LONG
(LONG FLUSH) OR FAILS TO SHUT OFF. |
|
|
|
CAUSE: |
|
|
A) By-pass
hole (upper filter ring) of diaphragm assembly is dirty. |
|
|
b) Relief valve or diaphragm
assembly is damaged. |
|
|
c) Water saver/ conventional
diaphragm assembly is installed on low consumption fixture
or closet diaphragm assembly is installed on urinal fixture. |
|
|
d) Inside cover is
damaged. |
|
|
E) Line water pressure
dropped and is insufficient to close valve. |
|
|
F) Relief
valve is not seated properly. |
|
|
|
SOLUTION: |
|
|
A) Remove
diaphragm assembly. Disassemble the filter rings from the diaphragm,
wash under running water, and reassemble. Replace as necessary. |
|
|
B) Replace
relief valve or diaphragm assembly. |
|
|
C) Determine
the required flush volume (see label on valve or markings on
fixture). Replace diaphragm assembly or relief valve for appropriate
flush volume for fixture. |
|
|
D) Install
new a-71 inside cover. |
|
|
E) Close
control stop until pressure is restored. |
|
|
F) Disassemble
diaphragm components (relief valve, filter rings, and diaphragm
unit), wash under running water, and reassemble. Replace as
necessary. |
|
|
|
|
| 7 |
PROBLEM: |
|
| |
CHATTERING NOISE IS HEARD
DURING FLUSH |
|
| |
CAUSE: |
|
| |
A) INSIDE
COVER IS DAMAGED |
| |
B) RELIEF
VALVE OR DIAPHRAGM ASSEMBLY IS DAMAGED |
|
| |
SOLUTION: |
|
| |
A) INSTALL
NEW INSIDE COVER |
| |
B) REPLACE
RELIEF VALVE OR DIAPHRAGM ASSEMBLY |
|
|
|
|
|
|
|
|
FOR BREAKDOWNS AND TROUBLESHOOTING
GUIDES
FOR OTHER SLOAN FLUSHOMETERS, CLICK HERE
|
|
|
|
|