1 |
PROBLEM: |
|
Faucet
does not function |
|
|
CAUSES: |
|
A) Adhesive
packaging label affixed over sensor eye. |
|
B) "Permanent
Off" activated |
|
|
SOLUTIONS: |
|
A) Remove
adhesive label from sensor eye. |
|
B) Press
button on faucet throat one time |
|
|
2 |
PROBLEM: |
|
|
Faucet
delivers water in an uncontrolled manner |
|
|
CAUSES: |
|
A) Faucet
is defective. |
|
|
SOLUTION: |
|
A) Contact
Equiparts, toll free, at 800-442-6622. |
|
|
3 |
PROBLEM: |
|
|
Faucet
does not deliver any water when sensor is activated. |
|
|
INDICATOR: |
|
|
Solenoid
valve produces an audible "CLICK". |
|
|
CAUSES: |
|
|
A) Water
supply stops(s) are closed. |
|
B) Water
supply stop strainer(s) are clogged. |
|
|
SOLUTIONS: |
|
|
A) Open
the Water Supply Stop(s) . |
|
B) Clean
water supply stop strainer(s). If strainers need to
be replaced, call Equiparts at 800-442-6622. |
|
|
INDICATOR: |
|
|
Solenoid
valve does NOT produce an audible "CLICK". |
|
|
CAUSES: |
|
|
A) Battery
low (EAF-150 models). |
|
|
SOLUTIONS: |
|
|
A) Replace
battery. Order battery # 08747 from Equiparts at 800-442-6622. |
|
|
4 |
PROBLEM: |
|
|
Faucet
delivers only a slow flow or dribble when sensor is activated |
|
|
CAUSE: |
|
|
A) Water
supply stops(s) are partially closed. |
|
B) Water
supply stop strainer(s) are clogged. |
|
C) Aerator
is clogged. |
|
D) Faucet
is defective. |
|
|
SOLUTIONS: |
|
A) Completely
open water supply stop(s). |
|
B) Remove,
clean, and reinstall water supply stop strainer(s). Replace
strainer, if needed, by ordering #
80759 from Equiparts at
800-442-6622. |
|
C) Remove,
clean, and reinstall aerator. Replace aerator, if needed,
by ordering # 80153 (2.2 gpm) or # 80757 (0.5
gpm) from Equiparts at
800-442-6622. |
|
D) Replace
solenoid. Order part # 58426 from Equiparts. Call 800-442-6622 for
additional assistance or to place an order. |
|
|
|
|
5 |
PROBLEM: |
|
|
Faucet
does not stop delivering water or continues to drip after
user is no longer detected. |
|
|
CAUSES: |
|
|
A) Faucet
is defective |
|
|
SOLUTION: |
|
A) Contact
Equiparts at 800-442-6622 |
|
6 |
PROBLEM: |
|
|
i.q.
cliq
doesn't function (-IC models only) . |
|
|
CAUSES: |
|
|
A) Button
is defective |
|
|
SOLUTION: |
|
A) Replace
with part # 58425. Call Equiparts at 800-442-6622 to order. |
|
|
7 |
PROBLEM: |
|
The
water temperature is too hot or too cold on a faucet
connected to hot and cold supply lines. |
|
|
CAUSES: |
|
A) Supply
stops are not adjusted properly. |
|
B) For
models with integral mixing valve, mixing valve is set improperly
for the water temperature desired. |
|
|
SOLUTIONS: |
|
A) Adjust
supply stops, or get a # 54621 Thermostatic Mixing
Valve to temper the water for the user. Call Equiparts at
800-442-6622 to order. |
|
B) Rotate
mixing valve handle clockwise to decrease water temperature
or counterclockwise to increase water temperature. |
|
|