SLOAN ELECTRONIC FAUCET REPAIR PARTS BREAKDOWN
ERF-885
Sloan ERF-885 Faucet Repair Parts
1
#
Faucet Spout and Sensor Assembly
2
#
0.5 gpm Spray Head w/Key (male thread)
3
# Replacement Key Only for ETF-234,
.5 gpm Spray Head
4
#
Faucet Mounting Kit includes Base Gasket, Flange Nut and ETF-297 Compression Fitting Connector
5A # 1/4" to 3/8" Tube Compression Fitting Connector
5B # Single Solenoid Supply Kit includes two Compression Nuts and two Compression Sleeves
6 # 3/8" Bak-Chek Tee Compression Fitting
7 # Control Module Assembly includes Base Enclosure, Cover Enclosure, two Gaskets, Solenoid Body, Solenoid Enclosure and Solenoid Filter Plug
7A
#
Solenoid Replacement Kit includes Solenoid Body, Solenoid Enclosure and Solenoid Filter Plug
8
#
Mounting Hardware Kit for Control Module Assembly includes four Anchor Nuts, four Toggle Nuts, four Mounting Screws for Base Plate, four Flat Washers, four Anchors, and four Metal Screws.
-
#
Solenoid Filter Replacement Kit (not shown) includes Filter Screen Assembly
-
#
Control Module Replacement Gasket (two required)
9A
#
4" Centerset Single-Hole Trim Plate Kit
9B
#
8" Centerset Single-Hole Trim Plate Kit
10
#
Below Deck Mechanical Water Mixing Valve
11
#
Below Deck Thermostatic Water Mixing Valve
12
#
Optimix Deck Mounted Water MIxing Valve
 
 
MAINTENANCE GUIDE FOR THE ERF-885 FAUCET
 
1
PROBLEM:
Control Module troubleshooting beeper does not function (no audio "beeps" sound during faucet initialization, battery install or after reset button is pressed.)
CAUSE:
A) No battery power is being supplied to Control Module
B) Insufficient battery power is being supplied to Control Module
SOLUTIONS:
A) Ensure that the batteries are installed properly intothe Control Module. Check that the orientation of each battery matches the positive and negative symbols shown on the bottom of the battery compartment. Reinsert the Battery Compartment into the Control Module. Make sure the Battery Connector is securely attached to the Battery Compartment. An audio "beep" should sound 6 times

B) One or more of the batteries is "dead." To ensure proper operation, replace with four C-size batteries
( order four # 32739 batteries from Equiparts by calling 800-442-6622.) Check that the orientation of each battery matches the positive and negative symbols shown on the bottom of the battery compartment. Reinsert the Battery Compartment into the Control Module.

2
PROBLEM:
Faucet does not deliver any water when Sensor is activated.
INDICATOR:
A) Solenoid valve produces an audible "click."
CAUSE:
A) Water supply valve is closed
SOLUTION:
A) Open the supply stop.
INDICATOR:
B) Solenoid valve does NOT produce an audible "click."
CAUSE:
B) Solenoid lead is not properly connected to the Control Module.
SOLUTION:
B) Disconnect and reconnect Solenoid lead to the Control Module.
CAUSE:
C) Batteries are not installed properly.
SOLUTION:
C) Check that the orientation of each battery matches the positive and negative symbols shown on the bottom of the battery compartment. Reinsert the battery compartment into the control module. The troubleshooting LED should flash red when a user is detected
3
PROBLEM:
Faucet delivers only a slow flow or dribble when sensor is activated.
CAUSES:
A) Water supply valve is partially closed.
B) Solenoid Filter is clogged.
C) Aerator or Spray Head is clogged.
D) Aerator needs replaced.
SOLUTIONS:
A) Completely open the Supply Stop.
B) Remove, clean, and reinsert. Replace (EBF-1004-A) Solenoid Filter Kit if necessary by ordering part # 08578 from Equiparts. Call 800-442-6622 to order.
C) Remove, clean, and reinsert.
D) Call Equiparts at 800-442-6622 to order new aerator.

4
PROBLEM:
Faucet does not stop delivering water or continues to drip after user is no longer detected (automatic shut-off fails even when batteries are removed.)
CAUSE:
A) Solenoid Valve has been connected backwards.
  B) Solenoid Valve is dirty.
  C) Solenoid Valve Module is defective.
 
SOLUTIONS:
A) Disassemble Solenoid Valve compression fittings at the inlet and outlet positions. Water should flow from inlet through the Solenoid Valve to outlet according to the direction shown by the arrow on the side of the Solenoid Valve. Reconnect the compression fittings in the correct orientation.
B) Back flush by reversing water flow, opposite to the direction shown by the arrow on the side of the Solenoid Valve, through the Solenoid Valve. Reconnect the compression fittings in the correct orientation. Activate faucet.
C) Replace Solenoid Valve Module. Call Equiparts at 800-442-6622 to order.

5
PROBLEM:
The water temperature is too hot or too cold on a faucet connected to hot and cold supply lines with Back Chek® Tee.
CAUSES:
A) Supply Stops are not adjusted properly.
SOLUTIONS:
A) Adjust Supply Stops
Equiparts  •   1003 Main St.  •  Pittsburgh, PA 15215
Pittsburgh: 412-781-9100   •  Toll Free: 800-442-6622   •   Fax: 412-781-3085
© 2008 Equiparts Corp. All Rights Reserved.