1
# 53814
Faucet and Sensor Assembly - EBF-85 with Black Plastic Throat
# 54695
Faucet and Sensor Assembly - EBF-187 with CP Metal Plastic Throat
# 54696
Fiber Optic Sensor Cable Assembly Only. (Replaces EBF-12-A, includes lens holder)
2
# 59857
0.5 gpm Spray Head w/Key (female thread)
# 55670
2.2 gpm Aerator Spray Head w/Key (female thread)
# 54677
2.2 gpm Laminar Flow Spray Head (female thread)
# 54693
Replacement Key only for ETF-1021-A 0.5 gpm Spray Head and ETF 1022-A 2.2 gpm Aerator Spray Head (NOT required for ETF-237 2.2 gpm Laminar Flow Spray Head)
3A
# 55154
4" Centerset Trim Plate Kit for EBF-85 or EBF-187 Faucet (Faucet only.) Includes 2 nuts, 2 hex screws, 2 flat plate washers, single hole CP cover plate, and black plastic base plate.
3B
# 54676
4" Centerset Trim Plate Kit for EBF-85 or EBF-187 Faucet (Faucet only.) Includes back-up spacer, self-tapping screw, and CP single hole trim plate assembly.
3C
# 54678
4" Centerset Trim Plate Kit for EBF-85 or EBF-187 Faucet with optional mixing valve. Includes back-up spacer, self-tapping screw, and CP dual hole trim plate assembly.
3D
# 52154
8" Centerset Trim Plate Kit for EBF-85 or EBF-187 Faucet (Faucet only.) Includes 2 finger nuts, 2 washer gaskets, 2 fender washers, base gasket, back-up spacer and CP single hole trim plate assembly,
3E
# 54679
8" Centerset Trim Plate Kit for EBF-85 or EBF-187 Faucet with optional mixing valve. Includes back-up spacer, self-tapping screw, and CP dual hole trim plate assembly.
     
4
# 59095
Faucet Mounting Kit includes rubber gasket, mounting washer, mounting nut and ETF-297 compression fitting connector.
5
# 54680
1/4" to 3/8" compression fitting connector.
6
# 54681
20" flex hose
     
7A
# 54003
Solenoid Valve Module Assembly for Battery Powered model. Includes solenoid enclosure, solenoid body, and filter cap
# 32739
"C" size Alkaline Batteries (four required)
7B
# 54697
Solenoid Valve Module Assembly for Transformer Powered mode (-R variation.) Includes solenoid enclosure, solenoid body, and filter cap.
# 8578
Solenoid Filter Replacement Kit. Includes filter screen assembly and O-Ring.
     
8A
# 27585
3/8" Ferrule
8B
# 27595
3/8" Compression Nut
9
# 8238
Mounting Bracket Kit. Includes base plate, wall bracket base, wall bracket, mounting screw, self-tapping screw, 2 wood screws plus washers and plastic anchors, 2 screws plus washers and toggle nuts, 2 screws plus washers and hollow wall anchors.
10
# 54682
3/8" Backcheck Tee
 
 
MAINTENANCE GUIDE FOR THE EBF-85, EBF-85-R, EBF-187, AND EBF-187-R FAUCET
 
1
PROBLEM:
  Module emits audible "beeps" when activated.
   
  CAUSE:
  Battery power is nearly exhausted.
   
  SOLUTION:
  To ensure proper operation, insert four (4) new C-size alkaline batteries. Check that the orientation of each battery matches the positive (+) and negative (-) symbols shown in the bottom of the Battery Compartment. Reattach Battery Compartment to Control Module.

2
PROBLEM:
  Sensor is activated but faucet does not deliver water.
   
  INDICATOR:
  Module does not produce audible "beeps."
   
  CAUSES:
  A) Battery power is fully exhausted.
  B) Batteries are not installed properly
  C) Solenoid Valve Module is defective
   
  SOLUTIONS:
  A) To ensure proper operation, insert four (4) new C-size alkaline batteries. Check that the orientation of each battery matches the positive(+) and negative(-) symbols shown in the bottom of the battery compartment. Reattach Battery Compartment to Control Module.
  B) Check that the orientation of each battery matches the positive (+) and negative (-) symbols shown in the bottom of the Battery Compartment. Reattach Battery Compartment to Control Module.
  C) Replace # 54003 (EBF-11-A) Solenoid Valve Module.
   
  INDICATOR:
  Module produces audible "beeps" when batteries are instaled and after a 30 second calibration procedure, but NOT when a target is placed in the detection zone of the sensor.
   
  CAUSES:
  D) Fiber Optic Cable is not connected correctly to Solenoid Valve Module, or was not connected when batteries were installed.
  E) Fiber Optic cable is defective.
  F) Solenoid Valve Module is defective
   
  SOLUTIONS:
  D) Reconnect Fiber Optic Cable to Solenoid Valve Module. Open Battery Compartment to reset electrical system. Check that the orientation of each battery matches the positive(+) and negative(-) symbols shown in the bottom of the Battery Compartment. Reattach Battery Compartment to Control Module.
  E) Replace # 54696 (EBF-1009-A) Sensor Cable, or # 53814 (EBF-10-A) Faucet Sensor Assembly.
  F) Replace # 54003 (EBF-11-A) Solenoid Valve Module
   
  INDICATOR:
  Module produces audible "beeps" when a target is placed in the detection zone of the sensor and Solenoid Valve produces an audible "click" but no water flows.
   
  CAUSES:
  G) Water supply to faucet is not open.
  H) Back Check is installed backwards
  I) Solenoid filter is clogged.
  J) Aerator or Spray Head is clogged.
   
  SOLUTIONS:
  G) Open supply stop(s)
  H) Reinstall back check(s)
  I) Remove, clean, and reinsert. Replace with # 8580 (EBF-1001-A) or # 8578 (EBF-1004-A).
  J) Remove, clean, and reinsert
   
  INDICATOR:
  Module produces audible "beeps" when a target is placed in the detection zone of the sensor, but Solenoid Valve does not produce an audible "click", and no water flows.
   
  CAUSE:
  K) Solenoid Valve Module is defective.
  SOLUTION:
  K) Replace # 54003 (EBF-11-A) Solenoid Valve Module
3
PROBLEM:
  Faucet delivers only a slow flow or dribble when sensor is activated.
     
  CAUSE:  
  A) Water supply valve is partially closed.
  B) Solenoid Filter is clogged.
  C) Aerator or Spray Head is clogged.
     
  SOLUTION:  
  A) Open the Supply Stop(s) completely.
  B) Remove, clean, and reinsert. Replace with # 8580 (EBF-1001-A) or # 8578 (EBF-1004-A) Solenoid Filter if necessary
  C) Remove, clean, and reinsert
   

4
PROBLEM:
  Faucet does not stop delivering water or continues to drip after user is no longer detected (automatic shut-off fails even when batteries are removed.)
     
  CAUSE:  
  A) Solenoid has been conected backwards.
  B) Solenoid Valve seat Is dirty
  C) Solenoid Valve is dirty.
  D) Solenoid Valve Module is defective.
     
  SOLUTIONS:
  A) Disassemble Solenoid Valve compression fittings at the inlet and outlet positions. Water should flow from inlet through the Solenoid Valve to outlet according to the direction shown by the arrow on the side of the Solenoid Valve. Reconnect the fittings in the correct orientation.
  B) Remove, clean, and reinsert Solenoid Filter. Activate faucet several times to flush out dirt.
  C) Backflush by reversing water flow (oposite to the direction shown by the arrow on the side of the Solenoid Valve) through the Solenoid Valve. Reconnect the compression fittings in the correct orientation. Activate faucet.
  D) Replace # 54003 (EBF-11-A) Solenoid Valve Module.

5
PROBLEM:
  The water temperature is too hot or too cold on a faucet connected to hot and cold supply lines with two Back Checks.
     
  CAUSES:  
  A) Supply Stops are not adjusted properly.
  B) One Back Check is installed backwards.
     
  SOLUTIONS:
  A) Adjust Supply Stops
  B) Reinstall Back Check

 

 

DOWNLOAD A PDF VERSION OF THIS GUIDE HERE.|||

||||