PROBLEM: |
|
Sensor is activated but faucet does not deliver water. |
|
|
INDICATOR: |
|
Module does not produce
audible "beeps." |
|
|
CAUSES: |
|
A) Battery
power is fully exhausted. |
|
B) Batteries
are not installed properly |
|
C) Solenoid Valve Module is defective |
|
|
SOLUTIONS: |
|
A) To
ensure proper operation, replace with four new C-size batteries
(order four # 32739 batteries from Equiparts by
calling 800-442-6622.) Check that the orientation
of each battery matches the positive and negative symbols
shown on the bottom of the battery compartment. Reattach
the Battery Compartment to the Control Module. |
|
B) Check
that the orientation of each battery matches the positive
(+) and negative (-) symbols shown in the bottom of the
Battery Compartment. Reattach Battery Compartment to Control
Module. |
|
C) Replace with #54003 (EBF-11-A)
Solenoid Valve Module. Call Equiparts at 800-442-6622
to order. |
|
|
INDICATOR: |
|
Module
produces audible "beeps" when batteries are
installed and after a 30 second calibration procedure,
but NOT when a target is placed in the detection zone
of the sensor. |
|
|
CAUSES: |
|
D) Fiber
Optic Cable is not connected correctly to Solenoid Valve
Module, or was not connected when batteries were installed. |
|
E) Fiber
Optic cable is defective. |
|
F) Solenoid
Valve Module is defective |
|
|
SOLUTIONS: |
|
D) Reconnect
Fiber Optic Cable to Solenoid Valve Module. Open Battery
Compartment to reset electrical system. Check that the
orientation of each battery matches the positive(+) and
negative(-) symbols shown in the bottom of the Battery
Compartment. Reattach Battery Compartment to Control Module. |
|
E) Replace
fiber optic cable with a #
54696 (EBF-1009-A) Sensor Cable,
or a # 53814 (EBF-10-A) Faucet
Sensor Assembly from Equiparts. To order, call 800-442-6622. |
|
F) Replace
with #
54003 (EBF-11-A) Solenoid Valve Module from Equiparts.
To order, call 800-442-6622. |
|
|
INDICATOR: |
|
Module
produces audible "beeps" when a target is
placed in the detection zone of the sensor and Solenoid
Valve produces an audible "click" but NO
water flows. |
|
|
CAUSES: |
|
G) Water
supply to faucet is not open. |
|
H) Back
Check is installed backwards |
|
I) Solenoid
filter is clogged. |
|
J) Aerator
or Spray Head is clogged. |
|
|
SOLUTIONS: |
|
G) Open
supply stop(s) |
|
H) Reinstall
back check(s) |
|
I) Remove,
clean, and reinsert. Replace with # 8580 (EBF-1001-A)
or # 8578 (EBF-1004-A). Call Equiparts
at 800-442-6622 to order. |
|
J) Remove,
clean, and reinsert. If aerator needs to be replaced, see
above parts list to determine which part number to order. |
|
|
INDICATOR: |
| |
Module
produces audible "beeps" when a target is
placed in the detection zone of the sensor, but Solenoid
Valve does not produce an audible "click",
and no water flows. |
|
|
CAUSES: |
|
K) Solenoid
Valve Module is defective. |
|
|
SOLUTIONS: |
|
K) Replace
with # 54003 (EBF-11-A) Solenoid Valve Module. To
order, call Equiparts at 800-442-6622. |
|
|